N.H. Admin. Code § Pes 804.08

Current through Register No. 2, January 9, 2025
Section Pes 804.08 - Secondary Containment Areas For Liquid Pesticides
(a) Any stationary liquid bulk container shall be protected by a secondary containment area which meets the provisions of Pes 804.04, Pes 804.05, Pes 804.06 and Pes 804.07 and the requirements of this section.
(b) A secondary containment area shall have, at a minimum, the following capacity, compensating for any volume displaced by containers and appurtenances:
(1) At least 125 percent of the capacity of the largest stationary bulk container within a secondary containment area that is not protected from precipitation; or
(2) At least 110 percent of the capacity of the largest stationary bulk container within a secondary containment area that is protected from precipitation.
(c) The secondary containment area shall allow for the observation of leakage from the base of any enclosed stationary bulk container. This requirement may be achieved by elevating the stationary bulk container on structures such as legs, skids, or by other methods, provided that leaked material can be observed readily and the integrity of the containment structure is preserved.
(d) The owner or operator of the secondary containment area shall ensure that each lockable valve on any stationary liquid bulk container is closed and locked or that the facility is locked whenever the facility is unattended.

N.H. Admin. Code § Pes 804.08

#5611, eff 4-13-93; amd by #5734, eff 11-5-93 (From Pes 803.07); ss and moved by #5766, eff 12-28-93 (From Pes 804.07); ss by #6317, eff 8-13-96; ss by #7987, eff 1-3-04, EXPIRED: 1-3-12

New. #10489, INTERIM, eff 12-17-13, EXPIRES: 6-16-14

Amended byVolume XXXV Number 01, Filed January 8, 2015, Proposed by #10712, Effective 11/5/2014, Expires11/5/2024.