N.H. Admin. Code § He-P 4001.09

Current through Register No. 45, November 7, 2024
Section He-P 4001.09 - Units of Exposure and Dose
(a) As used in these rules, the unit of exposure shall be the coulomb per kilogram (C/kg) of air.
(b) One roentgen shall be equal to 2.58 ×10-4 coulomb per kilogram of air.
(c) As used in these rules, the units of dose shall be:
(1) Gray (Gy) as defined in He-P 4003.01;
(2) Rad as defined in He-P 4003.01;
(3) Rem as defined in He-P 4003.01; or
(4) Sievert as defined in He-P 4003.01.
(d) As used in these rules, the quality factors for converting absorbed dose to dose equivalent shall be as in Table 4001.1:

Table 4001.1 Quality Factors and Absorbed Dose Equivalencies

Type of Radiation

Quality Factor (Q)

Absorbed Dose Equal to a Unit Dose Equivalent

X, gamma, or beta radiation and high speed electrons

1

1

Alpha particles, multiple-charged particles, fission fragments and heavy particles of unknown charge

20

0.05

Neutrons of unknown energy

10

0.1

High-energy protons

10

0.1

(e) If it is more convenient to measure the neutron fluence rate than to determine the neutron dose equivalent rate in sievert per hour or rem per hour, as provided in He-P 4001.09(f), 0.01 Sv (1 rem) of neutron radiation of unknown energies may, for purposes of these rules, be assumed to result from a total fluence of 25 million neutrons per square centimeter incident upon the body.
(f) If sufficient information exists to estimate the approximate energy distribution of the neutrons, the licensee or registrant may use the fluence rate per unit dose equivalent or the appropriate Q value from Table 4001.2 to convert a measured tissue dose in gray or rad to dose equivalent in sievert or rem.
(g) As used in these rules, the mean quality factors, Q, and fluence per unit dose equivalent for monoenergetic neutrons shall be as shown in Table 4001.2 below:

Table 4001.2 Mean Quality Factors, Q, and Fluence Per Unit Dose Equivalent for Monoenergetic Neutrons

Neutron Energy (MeV)

Quality Factor (Q)

Fluence per Unit Dose Equivalent

Click here to view image.

Fluence per Unit Dose Equivalent

Click here to view image.

(thermal)

2.5 × 10-8

2

980 × 106

980 × 108

1 × 10-7

2

980 × 106

980 × 108

1 × 10-6

2

810 × 106

810 × 108

1 × 10-5

2

810 × 106

810 × 108

1 × 10-4

2

840 × 106

840 × 108

1 × 10-3

2

980 × 106

980 × 108

1 × 10-2

2.5

1010 × 106

1010 × 108

1 × 10-1

7.5

170 × 106

170 × 108

5 × 10-1

11

39 × 106

39 × 108

1

11

27 × 106

27 × 108

2.5

9

29 × 106

29 × 108

5

8

23 × 106

23 × 108

7

7

24 × 106

24 × 108

10

6.5

24 × 106

24 × 108

14

7.5

17 × 106

17 × 108

20

8

16 × 106

16 × 108

40

7

14 × 106

14 × 108

60

5.5

16 × 106

16 × 108

100

4

20 × 106

20 × 108

200

3.5

19 × 106

19 × 108

300

3.5

16 × 106

16 × 108

400

3.5

14 × 106

14 × 108

(h) Value of quality factor (Q) in Table 4001.2 shall be the point where the dose equivalent is maximum in a 30-centimeter diameter cylinder tissue-equivalent phantom.
(i) Fluence per unit dose equivalent in Table 4001.2 shall be monoenergetic neutrons incident normally on a 30-centimeter diameter cylinder tissue-equivalent phantom.

N.H. Admin. Code § He-P 4001.09

#5903, eff 2-1-95; ss by #6827, eff 8-6-98 (renumbered by #8488, from He-P 4001.08); ss by #8692, INTERIM, eff 7-27-06, EXPIRES: 2-2-07; ss by #8808, eff 1-24-07

Amended byVolume XXXV Number 14, Filed April 9, 2015, Proposed by #10805, Effective 3/28/2015, Expires3/28/2025.
Amended by Number 15, Filed April 13, 2023, Proposed by #13599, Effective 3/24/2023, Expires 3/24/2033.