Section Env-Ws 372.27 - Criteria of the Technical Design ProposalThe technical design proposal required by Env-Ws 372.26(b)(4) shall:
(a) Identify the water treatment process to be used and the equipment to be installed;(b) Describe the chemical(s), plumbing, and electrical control modifications that represent a complete treatment process;(c) Include a tabular summary of laboratory sampling results analyzed by a New Hampshire-accredited laboratory, which identifies:(1) The contaminant(s) to be modified by the treatment process; and(2) All other water quality factors, by name and concentration, that are predicted to be modified by the treatment process;(d) Describe the expected water quality change by the water treatment process, including: (1) The concentration of the target contaminant at normal and peak production rates; and(2) The concentrations of all other affected water quality parameters at normal and peak production rates;(e) Identify the configuration of all components of the treatment process, including: (1) The rationale for a series or parallel configuration;(2) The number of trains of equipment; and(3) A description of each pretreatment process;(f) Describe the design goal of the treatment process, as follows:(1) Removal of the contaminant(s) to de minimis levels; or(2) A reduction of the contaminant so as to achieve compliance with the maximum contaminant levels or the maximum contaminant level goals specified in Env-Ws 311 through Env-Ws 315;(g) Identify, as appropriate, the criteria used for each treatment component of the process, including: (2) The detention time or empty bed contact time;(3) The backwash or regeneration flow rate required; and(4) The concentration of target contaminant selected to control the end of the treatment cycle;(h) Require a sampling tap to be installedbetween each treatment component of the treatment process and identify plumbing appurtenances throughout the treatment sequence, including: (1) Connecting pipe size, gate valves, check valves, unions, and bypasses;(2) Meter(s) and their type including whether indicating, totalizing, or recording; and(3) Flow restrictors and their rating;(i) Identify measuring, control, and communication/alarm equipment, including: (1) Chemical feed pump pacing method and associated equipment;(2) Flow switch interrupt of chemical feed equipment when there is no production flow; and(3) Other automatic monitoring and communication devices; and(j) For each treatment chemical to be used: (1) Identify the chemical and the anticipated concentration(s) to be used during both the initial start-up phase and the operational phase, if different; and(2) Include the following information: a. Documentation that the chemical is approved for drinking water use in accordance with the American National Standards Institute (ANSI) standard 60 as required in Env-Ws 305; andb. A copy of the material safety data sheet (MSDS) for that chemical.N.H. Admin. Code § Env-Ws 372.27
(See Revision Note at chapter heading Env-Ws 300) #6521, eff 6-4-97; ss by #8360, INTERIM, eff 6-4-05, EXPIRES: 12-1-05; ss by #8496, eff 11-30-05