N.H. Code Admin. R. Env-Wq 808.10

Current through Register No. 25, June 20, 2024
Section Env-Wq 808.10 - Soil Testing
(a) One soil test pit or auger boring shall be taken, at a depth of at least 40 inches, for each soil mapping unit present on the NRCS county soils map, but no less than one every 5 acres.
(b) One soil test pit or auger boring shall be taken, to a depth of at least 6 feet, for each area proposed for storage.
(c) An analysis of the soil test pits or auger borings required by (b) and (c), above, shall be performed and shall include a description of the soil profile characteristics, depth to the seasonal high water table, bedrock, or other restrictive layer.

N.H. Code Admin. R. Env-Wq 808.10

(See Revision Note at chapter heading for Env-Wq 800) #8887, eff 5-23-07