Section Env-Wq 1023.01 - Septic Tank Inspection and Pumping Requirements
(a) Septic tanks shall be inspected for accumulation of sludge and surface scum at a frequency sufficient to allow the tank to be pumped by a licensed septage hauler when the combined thickness of the sludge and surface scum equal 1/3 or more of the tank depth.
(b) For any septic tank having cast-in concrete baffles, the baffles shall be:
(1) Inspected for structural integrity when the tank is inspected pursuant to (a), above; and
(2) Replaced if no longer functioning as required.
(c) Septage and effluent shall be discharged from a septic tank only to:
(1) An approved or grandfathered effluent disposal area; or
(2) A licensed septage hauling vehicle.

N.H. Code Admin. R. Env-Wq 1023.01

(See Revision Note at chapter heading for Env-Wq 1000) #9086, eff 2-9-08