N.H. Code Admin. R. Env-Wq 1010.08

Current through Register No. 25, June 20, 2024
Section Env-Wq 1010.08 - Pipe to Tank Connections
(a) All connections between a septic tank and the pipes leading to and exiting from the septic tank shall be sealed with a watertight, flexible joint connector that:
(1) Will accommodate normal movement of the septic tank without leaking or breaking; and
(2) Has been certified by its manufacturer or distributer as meeting or exceeding the applicable standard in ASTM C 1644-06, section 7.
(b) The slope of the interior length of any pipe that extends into a septic tank shall not exceed the minimum pitch specified in Env-Wq 1009.06(a).

N.H. Code Admin. R. Env-Wq 1010.08

(See Revision Note at chapter heading for Env-Wq 1000) #9086, eff 2-9-08; ss by #9904-A, eff 4-16-11

Amended by Volume XXXVI Number 41, Filed October 13, 2016, Proposed by #11184, Effective 10/1/2016, Expires 10/1/2026.