N.H. Admin. Code § Env-Wq 1009.03

Current through Register No. 44, October 31, 2024
Section Env-Wq 1009.03 - Manholes and Clean-outs in Long Runs
(a) Manholes shall be provided every 350 feet in long sewer runs and at each change in slope or direction.
(b) Manholes shall conform to standards set for municipal installations in Env-Wq 700.
(c) When the run of a gravity sewer designed to carry solids is greater than 100 feet but less than 350 feet with no change in slope or direction such that manholes are not used, a clean-out shall be provided every 100 feet that does not have a septic tank tie-in.

N.H. Admin. Code § Env-Wq 1009.03

(See Revision Note at chapter heading for Env-Wq 1000) #9086, eff 2-9-08

Amended by Volume XXXVI Number 41, Filed October 13, 2016, Proposed by #11184, Effective 10/1/2016, Expires 10/1/2026.