N.H. Admin. Code § Env-Wq 1008.05

Current through Register No. 44, October 31, 2024
Section Env-Wq 1008.05 - Nitrate Setbacks to Property Lines
(a) The bed shall be located at or beyond the minimum distances from property lines as shown in Table 1008-3, below.
(b) Groundwater easements on abutting property may be used to meet setback distance requirements.
(c) An applicant may request a reduction in one or more of the minimum nitrate setback distances by submitting a hydrogeological analysis of the property demonstrating that the requirements of Env-Wq 402 will be met. If the department determines that the analysis validly demonstrates that the minimum specified nitrate setback distance is not required and the discharge is not prohibited by Env-Wq 402, the department shall approve a reduced setback.
(d) For non-aggregate flows of up to 999 GPD, the setback distance to any property line shall be as specified in Table 1008-2.
(e) If 2 or more EDA are proposed for a single lot and the total combined design flow equals 1,000 GPD or more, the setback distances for each bed shall be determined as follows:
(1) For any bed that is within the setback distance specified in (f), below, or Table 1008-3, below, as applicable, of any other bed on the same lot, the setback distances for both beds shall be as specified in Table 1008-3, below, for the total combined flow to the beds; and
(2) For any bed that is not within the setback distances specified in (f), below, or Table 1008-3, below, as applicable, of any other bed on the same lot, the setback distances for that bed shall be based on the flow to that bed, as follows:
a. If flow to the bed is less than 1,000 GPD, the distances to property lines shall be as specified in (d), above; or
b. If flow to the bed is 1,000 GPD or more, the distances to property lines shall be as specified in Table 1008-3, below.
(f) For purposes of determining whether a bed is within the setback distances of another bed on the same lot where the flow to one or both of the beds is less than 1,000 GPD, the setback distances shall be as follows:
(1) If the bed is hydraulically down-gradient, 50 feet;
(2) If the bed is hydraulically side-gradient, 25 feet; and
(3) If the bed is hydraulically up-gradient, 12 feet.
(g) Minimum nitrate setback distances to property lines and for use when determining whether (e)(1) or (e)(2), above, applies shall be as follows:

Table 1008-3: Minimum Nitrate Setback Distances (in feet)

Design Flow, GPD

HydraulicallyDown-gradient

HydraulicallySide-gradient

HydraulicallyUp-gradient

1,000-1,100

55

28

14

1,101-1,200

60

30

15

1,201-1,300

65

33

17

1,301-1,400

70

35

18

1,401-1,500

75

38

19

1,501-1,600

80

40

20

1,601-1,700

85

43

22

1,701-1,800

90

45

23

1,801-1,900

95

48

24

1,901-2,000

100

50

25

2,001-2,100

105

53

27

2,101-2,200

110

55

28

2,201-2,300

115

58

29

2,301-2,400

120

60

30

2,401-2,500

125

63

32

2,501-3,000

150

75

37

3,001-3,500

175

88

44

3,501-4,000

200

100

50

4,001-4,500

225

113

57

4,501-5,000

250

125

63

5,001-6,000

275

138

69

6,001-7,000

300

150

75

7,001-8,000

320

160

80

8,001-9,000

340

170

85

9,001-10,000

350

175

88

10,001-15,000

435

213

107

15,001-19,999

500

250

125

N.H. Admin. Code § Env-Wq 1008.05

(See Revision Note at chapter heading for Env-Wq 1000) #9086, eff 2-9-08; amd by #9904-A, eff 4-16-11

Amended by Volume XXXVI Number 41, Filed October 13, 2016, Proposed by #11184, Effective 10/1/2016, Expires 10/1/2026.