Current through Register No. 44, October 31, 2024
Section Env-Wq 1003.14 - Ledge Lot Specifications In addition to the requirements for an ISDS application established in Env-Wq 1003.12, the applicant designing an ISDS for a ledge lot shall:
(a) Specify the type of fill to be used to raise the bed to the appropriate height;(b) Specify the method of stabilization of the fill, including compaction method, layering, wetting, and stabilization period;(c) Supply test pit information to verify the nature of the receiving layer, both at the EDA and down-slope from the proposed EDA, as specified in Env-Wq 1006.04;(d) Show on the plan all bedrock exposures within 75 feet of the proposed EDA; and(e) Show on the plan all surface waters and drinking water supplies within 75 feet of the components of the proposed ISDS.N.H. Admin. Code § Env-Wq 1003.14
(See Revision Note at chapter heading for Env-Wq 1000) #9086, eff 2-9-08; ss by #9904-A, eff 4-16-11
Amended by Volume XXXVI Number 41, Filed October 13, 2016, Proposed by #11184, Effective 10/1/2016, Expires 10/1/2026.