N.H. Code Admin. R. Env-Hw 807.03

Current through Register No. 25, June 20, 2024
Section Env-Hw 807.03 - Off-Specification Used Oil
(a) Used oil shall be classified as off-specification used oil if the oil:
(1) Does not meet all of the standards in Table 8.1;
(2) Has not been mixed with hazardous waste; and
(3) Meets the standards in Table 8.2 below and does not otherwise exhibit any hazardous waste characteristics specified in Env-Hw 403:

Table 8.2 Off-Specification Used Oil Standards

Constituent/Property

Allowable Level

Arsenic

18 ppm-dw maximum

Cadmium

10 ppm-dw maximum

Chromium

35 ppm-dw maximum

Lead

1,000 ppm-dw maximum

Flash point

100 degrees Fahrenheit minimum

Total halogens

1,000 ppm-dw maximum, unless the presumption that the oil was mixed with halogenated hazardous waste has been rebutted as described in Env-Hw 807.04(c)

(b) Except as provided in Env-Hw 401.03(b)(26), used oil containing polychlorinated biphenyls (PCBs) at concentrations greater than or equal to 2 ppm shall be classified as off-specification used oil that is subject to all requirements for managing off-specification used oil in Env-Hw 807. Used oil containing PCBs also shall be subject to regulation under the Toxic Substances Control Act and its rules codified under 40 CFR Part 761.

N.H. Code Admin. R. Env-Hw 807.03

#5053, eff 1-24-91; ss by #5886, eff 8-26-94; amd by #6384-B, eff 11-26-96; ss by #7333, eff 8-1-00; amd by #7578, eff 10-13-01; ss by #9215, INTERIM, eff 8-1-08; (See Revision Note at chapter heading for Env-Hw 800) ss by #9367, eff 1-28-09

Amended by Volume XXXVII Number 32, Filed August 10, 2017, Proposed by #12350, Effective 8/14/2017, Expires 8/14/2027.