For a coating source that uses add-on control equipment or a bubble to achieve compliance with Env-A 1200, the overall emission standard shall be calculated as follows:
(a) "Pounds VOC per gallon of solids, emission standard (S)" means the VOC emission standard in terms of lb VOC/gal of coating solids, or kg VOC/l of coating solids, as applied;(b) "Pounds VOC per gallon of coating, emission standard (Ec)" means the VOC emission standard in terms of lb VOC/gal of coating, or kg VOC/l of coating, as applied, minus water and exempt compounds, obtained from the appropriate section of Env-A 1200;(c) "dA" means the actual mass density of the VOC in the applied surface coating formulation in terms of lb/gal or kg/l. For those stationary sources that have multiple coating lines feeding the add-on control equipment, dA means the weighted average actual mass density of the VOC in the applied surface coatings in terms of lb/gal or kg/l; and(d) S shall be equal to Ec divided by the difference between one and the quotient of Ec and dA, as in the following equation: Click here to view Image
N.H. Admin. Code § Env-A 804.07
#6087, eff 8-31-95 (formerly Env-A 804.05); ss by #7788, eff 10-31-02; ss by #9802, eff 10-31-10
Amended by Volume XXXIX Number 19, Filed May 9, 2019, Proposed by #12762, Effective 5/1/2019, Expires 5/1/2029.