N.H. Code Admin. R. Env-A 4609.12

Current through Register No. 25, June 20, 2024
Section Env-A 4609.12 - Procedures After Loss of Certification

If the department issues a notice of disapproval of a certification application under Env-A 4609.11(c) or a notice of disapproval of certification status under Env-A 4609.15(c) then:

(a) The owner or operator shall substitute the following values for each disapproved monitoring system, for each hour of unit operation during the period of invalid data beginning with the date and hour of provisional certification and continuing until the time, date, and hour specified under 40 CFR 75.20(a)(5)(i) or 40 CFR 75.20(g)(7):
(1) For units using or intending to monitor for CO2 mass emissions using heat input or for units using the low mass emissions excepted methodology under 40 CFR 75.19, the maximum potential hourly heat input of the unit as determined pursuant to (b), below; or
(2) For units intending to monitor for CO2 mass emissions using a CO2 pollutant concentration monitor and a flow monitor, the maximum potential concentration of CO2 and the maximum potential flow rate of the unit under section 2.1 of appendix A of 40 CFR part 75;
(b) If the owner or operator of a unit intends to use appendix D of 40 CFR Part 75 to report the heat input of a unit, the maximum potential hourly heat input of the unit shall be calculated, in accordance with 40 CFR Part 75, using the maximum fuel flow rate and the maximum gross calorific value. If the owner or operator of the unit intends to use a flow monitor and a diluent gas monitor, the maximum potential hourly heat input of the unit shall be reported, in accordance with 40 CFR Part 75, using the maximum potential flow rate and either the maximum carbon dioxide concentration, in percent CO2, or the minimum oxygen (O2) concentration, in percent O2;
(c) The CO2 AAR shall submit a notification of certification retest dates and a new certification application in accordance with Env-A 4609.08 and Env-A 4609.09; and
(d) The owner or operator shall repeat all certification tests or other requirements that were failed by the monitoring system, as indicated in the notice of disapproval, no later than 30 unit operating days after the date of issuance of the notice of disapproval.

N.H. Code Admin. R. Env-A 4609.12

#9283, INTERIM, eff 10-1-08, EXPIRED: 3-30-09

New. #9444, eff 4-3-09; ss by #10468, eff 1-1-14

Amended by Volume XL Number 2, Filed January 9, 2020, Proposed by #12967, Effective 1/1/2020, Expires 1/1/2030.