N.H. Admin. Code § Env-A 3511.01

Current through Register No. 45, November 7, 2024
Section Env-A 3511.01 - Performance and Compliance Testing for Small, Remote HMIWI Units
(a) The owner or operator of a small, remote HMIWI unit subject to the emission limits set forth in Env-A 3505.01(a) shall be subject to the following performance and compliance testing requirements:
(1) Performance and compliance testing shall be conducted in accordance with Env-A 3511.02, other than Env-A 3511.02 (a)(4)g, (e), and (f) for hydrogen chloride and Env-A 3511.02 (a)(4)h, (g), and (h) for lead and cadmium only;
(2) The annual performance testing procedure shall be conducted in accordance with Env-A 3511.03(a);
(3) The maximum charge rate and minimum secondary chamber temperature shall be established as site-specific operating parameters during the initial performance test to determine compliance with the applicable emission limits pursuant to Env-A 3505.01(a); and
(4) Following the date the initial performance test is completed or is required to be completed, the HMIWI unit shall not operate above the maximum charge rate or below the minimum secondary chamber temperature, measured as 3-hour rolling averages, calculated each hour as the average of the 3 previous operating hours, at all times except during periods of startup, shutdown, and malfunction.
(b) The owner or operator of a small, remote HMIWI shall not be subject to the 2,000 lb/week limitation pursuant to Env-A 3503.01(ar) during performance tests.

N.H. Admin. Code § Env-A 3511.01

#6938, eff 1-30-99; amd by #7127, eff 10-30-99; ss by #8788, eff 1-5-07