For the purpose of this chapter the following definitions shall apply:

(a) "Batch HMIWI" means "batch HMIWI" as defined in 40 CFR 60.51c, namely "an HMIWI that is designed such that neither waste charging nor ash removal can occur during combustion."
(b) "Biologicals" means "biologicals" as defined in 40 CFR 60.51c, namely "preparations made from living organisms and their products, including vaccines, cultures, etc., intended for use in diagnosing, immunizing, or treating humans or animals or in research pertaining thereto."
(c) "Blood products" means "blood products" as defined in 40 CFR 60.51c, namely "any product derived from human blood, including but not limited to blood plasma, platelets, red or white blood corpuscles, and other derived licensed products, such as interferon, etc."
(d) "Body fluids" means "body fluids" as defined in 40 CFR 60.51c, namely "liquid emanating or derived from humans and limited to blood; dialysate; amniotic, cerebrospinal, synovial, pleural, peritoneal and pericardial fluids; and semen and vaginal secretions."
(e) "Bypass stack" means "bypass stack" as defined in 40 CFR 60.51c, namely "a device used for discharging combustion gases to avoid severe damage to the air pollution control device or other equipment."
(f) "Chemotherapeutic waste" means "chemotherapeutic waste" as defined in 40 CFR 60.51c, namely "waste material resulting from the production or use of antineoplastic agents used for the purpose of stopping or reversing the growth of malignant cells."
(g) "Co-fired combustor" means "co-fired combustor" as defined in 40 CFR 60.51c, namely "a unit combusting hospital waste and/or medical/infectious waste with other fuels or wastes (e.g. coal, municipal solid waste) and subject to an enforceable requirement limiting the unit to combusting a fuel feed stream, 10 percent or less of the weight of which is comprised, in aggregate, of hospital waste and medical/infectious waste as measured on a calendar quarter basis. For purposes of this definition, pathological waste, chemotherapeutic waste, and low-level radioactive waste are considered other' wastes when calculating the percentage of hospital waste and medical/infectious waste combusted."
(h) "Continuous HMIWI" means "continuous HMIWI" as defined in 40 CFR 60.51c, namely "an HMIWI that is designed to allow waste charging and ash removal during combustion."
(i) "Dioxins/furans" means "dioxins/furans" as defined in 40 CFR 60.51c, namely "the combined emissions of tetra- through octa-chlorinated dibenzo-para-dioxins and dibenzofurans, as measured by EPA Reference Method 23."
(j) "Dry scrubber" means "dry scrubber" as defined in 40 CFR 60.51c, namely "an add-on air pollution control system that injects dry alkaline sorbent (dry injection) or sprays an alkaline sorbent (spray dryer) to react with and neutralize acid gases in the HMIWI exhaust stream forming a dry powder material."
(k) "Fabric filter" or "Baghouse" means "fabric filter" or "baghouse" as defined in 40 CFR 60.51c, namely "an add-on air pollution control system that removes particulate matter (PM) and nonvaporous metals emissions by passing flue gas through filter bags."
(l) "Facilities manager" means "facilities manager" as defined in 40 CFR 60.51c, namely "the individual in charge of purchasing, maintaining, and operating the HMIWI or the owner's or operator's representative responsible for the management of the HMIWI. Alternative titles may include director of facilities or vice president of support services."
(m) "High-air phase" means "high-air phase" as defined in 40 CFR 60.51c, namely "the stage of the batch operating cycle when the primary chamber reaches and maintains maximum operating temperatures."
(n) "Hospital" means "hospital" as defined in 40 CFR 60.51c, namely "any facility which has an organized medical staff, maintains at least six inpatient beds, and where the primary function of the institution is to provide diagnostic and therapeutic patient services and continuous nursing care primarily to human inpatients who are not related and who stay on average in excess of 24 hours per admission. This definition does not include facilities maintained for the sole purpose of providing nursing or convalescent care to human patients who generally are not acutely ill but who require continuing medical supervision."
(o) "Hospital/medical/infectious waste incinerator (HMIWI or HMIWI unit)" means "hospital/medical/infectious waste incinerator" or "HMIWI" or "HMIWI unit" as defined in 40 CFR 60.51c, namely "any device that combusts any amount of hospital waste and/or medical/infectious waste."
(p) "Hospital waste" means "hospital waste" as defined in 40 CFR 60.51c, namely "discards generated at a hospital, except unused items returned to the manufacturer. The definition of hospital waste does not include human corpses, remains, and anatomical parts that are intended for interment or cremation."
(q) "Infectious agent" means "infectious agent" as defined in 40 CFR 60.51c, namely "any organism (such as a virus or bacteria) that is capable of being communicated by invasion and multiplication in body tissues and capable of causing disease or adverse health impacts in humans."
(r) "Intermittent HMIWI" means "intermittent HMIWI" as defined in 40 CFR 60.51c, namely "an HMIWI that is designed to allow waste charging, but not ash removal, during combustion."
(s) "Large HMIWI" means:
(1) An HMIWI whose maximum design waste burning capacity is more than 500 pounds per hour;
(2) A continuous or intermittent HMIWI whose maximum charge rate is more than 500 pounds per hour; or
(3) A batch HMIWI whose maximum charge rate is more than 4,000 pounds per day.
(t) "Low-level radioactive waste" means "low-level radioactive waste" as defined in 40 CFR 60.51c, namely "waste material which contains radioactive nuclides emitting primarily beta or gamma radiation, or both, in concentrations or quantities that exceed applicable federal or State standards for unrestricted release. Low-level radioactive waste is not high-level radioactive waste, spent nuclear fuel, or by-product material as defined by the Atomic Energy Act of 1954 ( 42 U.S.C. 2014(e)(2) )."
(u) "Maximum charge rate" means "maximum charge rate" as defined in 40 CFR 60.51c, namely:
(1) "For continuous and intermittent HMIWI, 110 percent of the lowest 3-hour average charge rate measured during the most recent performance test demonstrating compliance with all applicable emission limits; or
(2) For batch HMIWI, 110 percent of the lowest daily charge rate measured during the most recent performance test demonstrating compliance with all applicable emission limits."
(v) "Maximum fabric filter inlet temperature" means "maximum fabric filter inlet temperature" as defined in 40 CFR 60.51c, namely "110 percent of the lowest 3-hour average temperature at the inlet to the fabric filter (taken, at a minimum, once every minute) measured during the most recent performance test demonstrating compliance with the dioxin/furan emission limit."
(w) "Maximum flue gas temperature" means "maximum flue gas temperature" as defined in 40 CFR 60.51c, namely "110 percent of the lowest 3-hour average temperature at the outlet from the wet scrubber (taken, at a minimum, once every minute) measured during the most recent performance test demonstrating compliance with the mercury (Hg) emission limit."
(x) "Medical/infectious waste" means "medical/infectious waste" as defined in 40 CFR 60.51c, namely "any waste generated in the diagnosis, treatment, or immunization of human beings or animals, in research pertaining thereto, or in the production or testing of biologicals that is listed in paragraphs (1) through (7) of this definition. The definition of medical/infectious waste does not include hazardous waste identified or listed under the regulations in part 261 of this chapter; household waste, as defined in Sec. 261.4(b)(1) of this chapter; ash from incineration of medical/infectious waste, once the incineration process has been completed; human corpses, remains, and anatomical parts that are intended for interment or cremation; and domestic sewage materials identified in Sec. 261.4(a)(1) of this chapter.
(1) Cultures and stocks of infectious agents and associated biologicals, including: cultures from medical and pathological laboratories; cultures and stocks of infectious agents from research and industrial laboratories; wastes from the production of biologicals; discarded live and attenuated vaccines; and culture dishes and devices used to transfer, inoculate, and mix cultures.
(2) Human pathological waste, including tissues, organs, and body parts and body fluids that are removed during surgery or autopsy, or other medical procedures, and specimens of body fluids and their containers.
(3) Human blood and blood products including:
a. Liquid waste human blood;
b. Products of blood;
c. Items saturated and/or dripping with human blood; or
d. Items that were saturated and/or dripping with human blood that are now caked with dried human blood; including serum, plasma, and other blood components, and their containers, which were used or intended for use in either patient care, testing and laboratory analysis or the development of pharmaceuticals. Intravenous bags are also included in this category.
(4) Sharps that have been used in animal or human patient care or treatment or in medical, research, or industrial laboratories, including hypodermic needles, syringes (with or without the attached needle), Pasteur pipettes, scalpel blades, blood vials, needles with attached tubing, and culture dishes (regardless of presence of infectious agents). Also included are other types of broken or unbroken glassware that were in contact with infectious agents, such as used slides and cover slips.
(5) Animal waste including contaminated animal carcasses, body parts, and bedding of animals that were known to have been exposed to infectious agents during research (including research in veterinary hospitals), production of biologicals or testing of pharmaceuticals.
(6) Isolation wastes including biological waste and discarded materials contaminated with blood, excretions, exudates, or secretions from humans who are isolated to protect others from certain highly communicable diseases, or isolated animals known to be infected with highly communicable diseases.
(7) Unused sharps including the following unused, discard sharps: hypodermic needles, suture needles, syringes, and scalpel blades."
(y) "Medium HMIWI" means:
(1) An HMIWI whose maximum design waste burning capacity is more than 200 pounds per hour but less than or equal to 500 pounds per hour; or
(2) A continuous or intermittent HMIWI whose maximum charge rate is more than 200 pounds per hour but less than or equal to 500 pounds per hour; or
(3) A batch HMIWI whose maximum charge rate is more than 1,600 pounds per day but less than or equal to 4,000 pounds per day.
(z) "Minimum dioxin/furan sorbent flow rate" means "minimum dioxin/furan sorbent flow rate" as defined in 40 CFR 60.51c, namely "90 percent of the highest 3-hour average dioxin/furan sorbent flow rate (taken, at a minimum, once every hour) measured during the most recent performance test demonstrating compliance with the dioxin/furan emission limit."
(aa) "Minimum Hg sorbent flow rate" means "minimum Hg sorbent flow rate" as defined in 40 CFR 60.51c, namely "90 percent of the highest 3-hour average Hg sorbent flow rate (taken, at a minimum, once every hour) measured during the most recent performance test demonstrating compliance with the Hg emission limit."
(ab) "Minimum hydrogen chloride sorbent flow rate" means "minimum hydrogen chloride sorbent flow rate" as defined in 40 CFR 60.51c, namely "90 percent of the highest 3-hour average HCl sorbent flow rate (taken, at a minimum, once every hour) measured during the most recent performance test demonstrating compliance with the HCl emission limit."
(ac) "Minimum horsepower or amperage" means "minimum horsepower or amperage" as defined in 40 CFR 60.51c, namely "90 percent of the highest 3-hour average horsepower or amperage to the wet scrubber (taken, at minimum, once every minute) measured during the most recent performance test demonstrating compliance with the applicable emission limits."
(ad) "Minimum pressure drop across the wet scrubber" means "minimum pressure drop across the wet scrubber" as defined in 40 CFR 60.51c, namely "90 percent of the highest 3-hour average pressure drop across the wet scrubber PM control device (taken, at a minimum, once every minute) measured during the most recent performance test demonstrating compliance with the PM emission limit."
(ae) "Minimum scrubber liquor flow rate" means "minimum scrubber liquor flow rate" as defined in 40 CFR 60.51c, namely "90 percent of the highest 3-hour average liquor flow rate at the inlet to the wet scrubber (taken, at a minimum, once every minute) measured during the most recent performance test demonstrating compliance with all applicable emission limits."
(af) "Minimum scrubber liquor pH" means "minimum scrubber liquor pH" as defined in 40 CFR 60.51c, namely "90 percent of the highest 3-hour average liquor pH at the inlet to the wet scrubber (taken, at a minimum, once every minute) measured during the most recent performance test demonstrating compliance with the HCl emission limit."
(ag) "Minimum secondary chamber temperature" means "minimum secondary chamber temperature" as defined in 40 CFR 60.51c, namely "90 percent of the highest 3-hour average secondary chamber temperature (taken, at a minimum, once every minute) measured during the most recent performance test demonstrating compliance with the PM, CO, or dioxin/furan emission limits."
(ah) "Modified HMIWI" means "modified HMIWI" as defined in 40 CFR 60.51c, namely "any change to an HMIWI unit after January 30, 1999 such that:
(1) The cumulative costs of the modifications, over the life of the unit, exceed 50 per centum of the original cost of the construction and installation of the unit, not including the cost of any land purchased in connection with such construction or installation, updated to current costs; or
(2) The change involves a physical change in or change in the method of operation of the unit which increases the amount of any air pollutant emitted by the unit for which standards have been established under section 129 or section 111 of the Clean Air Act."
(ai) "Operating day" means "operating day" as defined in 40 CFR 60.51c, namely "a 24-hour period between 12:00 midnight and the following midnight during which any amount of hospital waste or medical/infectious waste is combusted at any time in the HMIWI."
(aj) "Operation" means "operation" as defined in 40 CFR 60.51c, namely "the period during which waste is combusted in the incinerator excluding periods of startup or shutdown."
(ak) "Pathological waste" means "pathological waste" as defined in 40 CFR 60.51c, namely "waste material consisting of only human or animal remains, anatomical parts, and/or tissue, the bags/containers used to collect and transport the waste material, and animal bedding, if applicable."
(al) "Primary chamber" means "primary chamber" as defined in 40 CFR 60.51c, namely "the chamber in an HMIWI that receives waste material, in which the waste is ignited, and from which ash is removed."
(am) "Pyrolysis" means "pyrolysis" as defined in 40 CFR 60.51c, namely "the endothermic gasification of hospital waste and/or medical/infectious waste using external energy."
(an) "Secondary chamber" means "secondary chamber" as defined in 40 CFR 60.51c, namely "a component of the HMIWI that receives combustion gases from the primary chamber and in which the combustion process is completed."
(ao) "Section 111(d)/129 state plan" means the written document required to be submitted to EPA following adoption of this chapter by the state and which implements the regulations controlling air pollutant emissions from hospital/medical/infectious waste incinerators, pursuant to this chapter.
(ap) "Shutdown" means "shutdown" as defined in 40 CFR 60.51c, namely "the period of time after all waste has been combusted in the primary chamber. For continuous HMIWI, shutdown shall commence no less than 2 hours after the last charge to the incinerator. For intermittent HMIWI, shutdown shall commence no less than 4 hours after the last charge to the incinerator. For batch HMIWI, shutdown shall commence no less than 5 hours after the high-air phase of combustion has been completed."
(aq) "Small HMIWI" means:
(1) An HMIWI whose maximum design waste burning capacity is less than or equal to 200 pounds per hour;
(2) A continuous or intermittent HMIWI whose maximum charge rate is less than or equal to 200 pounds per hour; or
(3) A batch HMIWI whose maximum charge rate is less than or equal to 1,600 pounds per day.
(ar) "Small, remote HMIWI" means any small HMIWI which is located more than 50 miles from the boundary of the nearest Standard Metropolitan Statistical Area (SMSA) and burns less than 2,000 pounds per week of hospital waste and medical/infectious waste.
(as) "Standard Metropolitan Statistical Area (SMSA)" means "standard metropolitan statistical area" or "SMSA" as defined in 40 CFR 60.31e, namely "any areas listed in the Office of Management and Budget Bulletin No. 93-17 entitled "Revised Statistical Definitions for Metropolitan Areas" dated June 30, 1993."
(at) "Startup" means "startup" as defined in 40 CFR 60.51c, namely "the period of time between the activation of the system and the first charge to the unit. For batch HMIWI, startup means the period of time between activation of the system and ignition of the waste."
(au) "Toxic equivalency (TEQ)" means the product of the individual dioxin/furan compound concentrations and their respective toxic equivalency factor.
(av) "Toxic equivalency factor (TEF)" means the estimate of the toxicity of dioxin-like compounds, or congeners, relative to the toxicity of 2,3,7,8-TCDD, which is assigned a TEF of 1.0.
(aw) "Wet scrubber" means "wet scrubber" as defined in 40 CFR 60.51c, namely "an add-on air pollution control device that utilizes an alkaline scrubbing liquor to collect particulate matter (including nonvaporous metals and condensed organics) and/or to absorb and neutralize acid gases."