N.H. Code Admin. R. Env-A 1808.03

Current through Register No. 25, June 20, 2024
Section Env-A 1808.03 - Analytical Techniques
(a) Air samples shall be submitted for analysis to a laboratory that uses phase contrast microscopy (PCM) for the analysis of air samples for asbestos content unless accredited by the National Institute of Standards and Technology (NIST) for transmission electron microscopy (TEM), in which case the laboratory may analyze air samples using TEM.
(b) Analytical procedures for PCM shall be in accordance with NIOSH Method 7400, Issue 2, entitled "Fibers" published in the NIOSH Manual of Analytical Methods, 4th Edition, Second Supplement, August 1994, available as noted in Appendix B. Air volumes sampled shall be sufficient to accurately determine, to a 95 percent probability, fiber concentrations of 0.01 fibers/cubic centimeters of air (f/cc).
(c) Analytical procedures for TEM shall be as stated in 40 CFR Part 763, subpart E, appendix A: "Mandatory and Non-Mandatory" or as defined and accepted by the NIST for TEM accreditation.
(d) Analytical procedures for PLM shall be as stated in 40 CFR Part 763, subpart F, appendix A: "Interim Method of the Determination of Asbestos in Bulk Insulation Samples" or as defined and accepted by the NIST for PLM accreditation.

N.H. Code Admin. R. Env-A 1808.03

(See Revision Note at chapter heading for Env-A 1800) #9298, eff 10-21-08

Amended by Volume XXXVII Number 19, Filed May 11, 2017, Proposed by #12172, Effective 5/5/2017, Expires 5/5/2027.