N.H. Code Admin. R. Env-A 1806.02

Current through Register No. 25, June 20, 2024
Section Env-A 1806.02 - Abatement of Vinyl Asbestos-Containing Floor Coverings and Mastic

The following provisions of Env-A 1805.04(h) shall be modified as noted for facility O/Os who do not saw, grind, or abrade a vinyl floor and who do not separate sheet vinyl flooring from its backing:

(a) Ceiling sheeting as specified in Env-A 1805.04(h)(1) and (5) shall not be required; and
(b) Wall sheeting as specified in Env-A 1805.04(h)(1) and (4) shall be 4 mil or thicker and cover the bottom 4 feet of each wall.

N.H. Code Admin. R. Env-A 1806.02

(See Revision Note at chapter heading for Env-A 1800) #9298, eff 10-21-08

Amended by Volume XXXVII Number 19, Filed May 11, 2017, Proposed by #12172, Effective 5/5/2017, Expires 5/5/2027.