N.H. Code Admin. R. Env-A 1310.04

Current through Register No. 25, June 20, 2024
Section Env-A 1310.04 - Emission Standards for Wallboard Manufacturing Facilities Firing Oil

For wallboard dryers, calcining mills, calciners, and gypsum rock dryers firing fuel oil, the NOx RACT requirements shall be as follows:

(a) When firing No. 2 fuel oil:
(1) An emission limit of 0.10 lb. per million Btu, based on an hourly average; or
(2) Implement NOx RACT control technology as specified in Env-A 1310.02(b); and
(b) When firing No. 4, No. 5, or No. 6 fuel oil:
(1) An emission limit of 0.30 lb. per million Btu, based on a 24-hour calendar day average; or
(2) Implement NOx RACT control technology as specified in Env-A 1310.02(b).

N.H. Code Admin. R. Env-A 1310.04

(See Revision Note at chapter heading for Env-A 1300) #9803, eff 10-31-10

Amended by Volume XXXVIII Number 32, Filed August 9, 2018, Proposed by #12584, Effective 8/15/2018, Expires 8/15/2028.