Current through December 12, 2024
Section 618.5259 - Safe temperature for drying ammonium perchlorate; mechanism for controlling temperature1. A safe temperature for drying ammonium perchlorate must be established by the employer and identified in the written procedure established for that operation.2. Equipment used for drying must be equipped with a mechanism for controlling the temperature when it exceeds the safe temperature. The mechanism must operate on an independent electrical circuit and have a manual reset switch.Nev. Admin. Code § 618.5259
Added to NAC by Div. of Enforcement for Industrial Safety & Health, 1-22-92, eff. 3-1-92