Nev. Admin. Code § 444.815

Current through December 12, 2024
Section 444.815 - Plumbing accessory structure into system serving single-family dwelling
1. An accessory structure may be allowed to plumb into an individual sewage disposal system that serves a single-family dwelling if:
(a) The accessory structure is used in conjunction with the single-family dwelling; and
(b) The septic tank has sufficient capacity to accommodate the total number of fixtures in the accessory structure and the single-family dwelling, as determined by the following table:

TYPE OF FIXTURE FIXTURE UNITS
Bathtub 2
Bidet 2
Drinking fountain 1
Floor drain 2
Interceptor:
For items such as grease, oil or solids 3
Laundry tub 2
Machine for washing clothes 2
Sewer connection for a recreational vehicle 6
Shower, single stall 2
Sink:
Bar, private (1 1/2-inch or 38.1 -millimeter minimum waste) 1
Bathroom (single) 1
Bathroom (double) 2
Kitchen, with or without dishwasher (2-inch or 50.8 -millimeter minimum waste) 2
Service 3
Toilet 6
Urinal 2

2. For the purposes of this section, each fixture unit must be rated at 25 gallons.

Nev. Admin. Code § 444.815

Added to NAC by Bd. of Health by R100-07, eff. 10-31-2007

NRS 439.200, 444.650