Nev. Admin. Code § 444.7962

Current through December 31, 2024
Section 444.7962 - Determination of appropriate percolation test procedure

In conducting a percolation test, the following flow chart must be used to determine which test procedure to follow:

1) Fill the percolation hole with water to a depth of at least 12 inches over the aggregate. Determine the time needed for the water to seep away completely.
2) Fill the percolation hole with water again to a depth of at least 12 inches over the aggregate. Determine if the water seeps away in 10 minutes or less.
3a) If water is left in the percolation hole after 10 minutes, proceed with the PRESOAKING PROCEDURE, followed by the SLOW PERCOLATION TEST PROCEDURE. 3b) If the water has completely seeped away after 10 minutes, proceed with the FAST PERCOLATION TEST PROCEDURE.

Nev. Admin. Code § 444.7962

Added to NAC by Bd. of Health by R129-98, eff. 3-25-99

NRS 439.200, 444.650