Current through September 17, 2024
Section 180-9-008 - WARNING DEVICESParticle accelerators must be equipped with warning devices as required below.
008.01LOCATION. Each location designated as a high radiation area, and each entrance to that location, must be equipped with easily observable warning lights that operate when, and only when, radiation is being produced.008.02AUDIBLE WARNING DEVICE. Each high radiation area must have an audible warning device which must be activated for 15 seconds prior to the possible creation of a high radiation area. The warning device must be clearly discernible in all high radiation areas and all radiation areas.008.03BARRIERS. Barriers, temporary or otherwise, and pathways leading to high radiation areas must be identified as required by 180 NAC 4-033.180 Neb. Admin. Code, ch. 9, § 008
Amended effective 6/26/2021