180 Neb. Admin. Code, ch. 5, § 039

Current through September 17, 2024
Section 180-5-039 - SPECIFIC REQUIREMENTS FOR RADIOGRAPHIC PERSONNEL PERFORMING INDUSTRIAL RADIOGRAPHY
039.01JOB SITE REQUIREMENTS. At a job site, the following must be supplied by the licensee or registrant:
(A) At least one operable, calibrated survey instrument for each exposure device or radiation machine in use;
(B) A current whole body personnel dosimeter for each person performing radiographic operations;
(C) An operable, calibrated pocket dosimeter with a range of zero to 200 milliroentgens for each person performing radiographic operations;
(D) An operable, calibrated, alarming ratemeter for each person performing radiographic operations using a radiographic exposure device; and
(E) The appropriate barrier ropes and signs.
039.02IDENTIFICATION CARD. Each radiographer at a job site must have on their person a valid certification identification card issued by a certifying entity.
039.03LIMITATIONS. Industrial radiographic operations must not be performed if any of the items in 180 NAC 5-039.01 and 5-039.02 are not available at the job site or are inoperable.

180 Neb. Admin. Code, ch. 5, § 039

Amended effective 11/1/2020
Amended effective 6/14/2023