Section 180-19-015 - POWER FAILURESSystems must function properly in the event of a power failure.
015.01POWER LOSS. If electrical power at a panoramic irradiator is lost for longer than ten seconds, the sources must automatically return to the shielded position.015.02LOCK. The lock on the door of the radiation room of a panoramic irradiator may not be deactivated by a power failure.015.03SURVEY METER. During a power failure, the area of any irradiator where sources are located may be entered only when using an operable and calibrated radiation survey meter.180 Neb. Admin. Code, ch. 19, § 015