180 Neb. Admin. Code, ch. 19, § 015

Current through September 17, 2024
Section 180-19-015 - POWER FAILURES

Systems must function properly in the event of a power failure.

015.01POWER LOSS. If electrical power at a panoramic irradiator is lost for longer than ten seconds, the sources must automatically return to the shielded position.
015.02LOCK. The lock on the door of the radiation room of a panoramic irradiator may not be deactivated by a power failure.
015.03SURVEY METER. During a power failure, the area of any irradiator where sources are located may be entered only when using an operable and calibrated radiation survey meter.

180 Neb. Admin. Code, ch. 19, § 015

Amended effective 6/26/2021
Amended effective 6/14/2023