Mont. Admin. R. 37.96.404

Current through Register Vol. 11, June 7, 2024
Rule 37.96.404 - BUILDING REQUIREMENTS RELATED TO EXITS
(1) In an emergency, all occupants must be able to escape from a child care facility in a safe and timely manner.
(a) Doorways, aisle ways, corridors, and stairs must be clear of any obstruction.
(i) Gates or guards at the top and bottom of stairways are allowed if they have latching devices that are easily opened by adults in case of emergency.
(ii) Sleeping equipment must be arranged to permit easy access to every child and unobstructed means of egress.
(2) All facilities must have two exits that create remote means of egress on each level that is used for child care.
(a) All nap rooms must have at least two means of egress.
(b) Exits/means of egress must meet the following requirements:
(i) one exit must be a door that is at least 32 inches wide and 80-inches tall; and
(ii) the second exit may be a window that provides a clear opening of at least 20 inches in width or 24 inches in height and 5.7 square feet in area. The bottom of the exit must not be more than 44 inches above the floor.
(3) Exit doors, windows, and their opening hardware must be maintained in good repair.
(4) If a child care provider chooses to lock exterior facility doors to prevent unauthorized access to the facility or to prevent a child from escaping, the lock:
(a) may not prevent free escape from the interior;
(b) must be easily opened with one motion from the inside of the facility; and
(c) may not prohibit access by parents/guardians. A facility may not use locking devices to prevent unannounced access by authorized individuals, including parents/guardians. If a lock is used, the provider must make adequate provision to allow authorized persons unannounced access to the facility and must provide authorized persons with information about how to gain access.
(5) Children must be able to open every closet door from the inside without a key, a tool, or special knowledge or effort.
(6) Every bathroom door must be designed to permit opening of the locked door from the outside in an emergency. The opening device must be readily accessible.
(7) This rule applies to all licensed and registered child care facilities except RCE facilities.

Mont. Admin. R. 37.96.404

NEW, 2024 MAR p. 738, Eff. 4/13/2024

AUTH: 52-2-704, 52-2-731, MCA; IMP: 52-2-702, 52-2-704, 52-2-723, 52-2-724, 52-2-731, 52-2-734, 52-2-735, MCA