PURPOSE: This rule provides the minimum criteria for the preparation of engineering reports and facility plans and specifications related to the design of wastewater systems. This rule is to be used with rules 10 CSR 20-8.110 through 10 CSR 20-8.210 for the planning and design of a wastewater treatment facility. It does not address all aspects of design, and the design engineer may refer to other appropriate reference materials so long as these minimum standards set forth in this rule are met.
Equation 110-1. Ratio of peak hourly flow to design average flow.
Peaking Factor = Q Peak Hourly / Q Design Avg = (18 + [ROOT]P) / (4 + [ROOT]P)
Where:
Q Peak Hourly = design peak hourly flow
Q Design Avg = design average flow
P = Population in thousands
These plans must show the following:
10 CSR 20-8.110