Current through December 10, 2024
Rule 15-16-1-41.84.26 - PFER Resuscitation RoomAll items listed for general examination rooms plus:
1. Adult and Pediatric "code cart" to include appropriate medication charts2. Capability for direct communication with nursing station, preferably hands free4. Radiographic view boxes and hot light5. Airways needs A. Big-valve-mask respirator (adult, pediatric, and infant) Cricothyroidotomyinstruments and suppliesB. Endotracheal tubes, size 2.5 to 8.5 mmC. Fiberoptic laryngoscopeD. Laryngoscopes, straight and curved blades and styletsE. Laryngoscope mirror and suppliesF. Laryngeal Mask Airway (LMA)G. Oral and nasal airwaysH. Tracheostomy instrument and supplies6. Breathing A. BiPAP Ventilation SystemB. Closed-chest drainage deviceC. Chest tube instruments and suppliesD. Emergency thoracotomy instruments and suppliesE. End-tidal C02 monitor 18I. Volume cycle ventilator7. Circulation A. Automatic physiological monitor, noninvasiveB. Blood/fluid infusion pumps and tubingD. Cardiac compression boardE. Central venous catheter setups/kitsF. Central venous pressure monitoring equipmentG. Cutdown instruments and suppliesI. IV catheters, sets, tubing, polesJ. Monitor/defibrillator with pediatric paddles, internal paddles, appropriate pads and other supplies Pericardiocentesis instrumentsK. Temporary external pacemakerL. Transvenous and/or transthoracic pacemaker setup and supplies15 Miss. Code. R. 16-1-41.84.26