SIZING - AGGREGATE REPLACEMENT (Expanded Polystyrene System) "Horizontal" Configuration
Results of the Soil and Site Evaluation
Soil Textural Class | Ribbon Lengths (Inches) | EPA Manual Application Rate GPD/ Ft2 | Absorption Area Per Bedroom** | Additional Absorption Over 2 Person Per Bedroom** | ||||||||||
3-1 0H | 1-12 | 2-12 | 3-12 | 1-14 | 3-10 H | 1-12 | 2-12 | 3-12 | 1-14 | |||||
Ft 2 | Lf | Lf | Lf | Lf | Lf | Ft 2 | Lf | Lf | Lf | Lf | Lf | |||
Gravel | - | - | NOT SUITABLE | |||||||||||
Coarse Sand | - | 1.2 | 108 | 30 | 75 | 37 | 25 | 36 | 54 | 15 | 38 | 19 | 13 | 18 |
Medium Sand | - | 1.2 | 108 | 30 | 75 | 37 | 25 | 36 | 54 | 15 | 38 | 19 | 13 | 18 |
Fine Sand | - | 0.8 | 163 | 46 | 114 | 57 | 38 | 55 | 81 | 23 | 57 | 29 | 19 | 28 |
Loamy Sand | - | 0.8 | 163 | 46 | 114 | 57 | 38 | 55 | 81 | 23 | 57 | 29 | 19 | 28 |
Sandy Loam | <.5 | 0.6 | 217 | 60 | 151 | 75 | 50 | 72 | 108 | 30 | 76 | 38 | 25 | 36 |
Light Loam | <.5 | 0.6 | 217 | 60 | 151 | 75 | 50 | 72 | 108 | 30 | 76 | 38 | 25 | 36 |
Heavy Loam | .5 - 1 | 0.45 | 289 | 81 | 201 | 101 | 67 | 97 | 144 | 40 | 101 | 52 | 33 | 49 |
Silt Loam | <1 | 0.45 | 289 | 81 | 201 | 101 | 67 | 97 | 144 | 40 | 101 | 52 | 33 | 49 |
Sandy Clay Loam | 1 - 2 | 0.45 | 289 | 81 | 201 | 101 | 67 | 97 | 144 | 40 | 101 | 52 | 33 | 49 |
Light Clay Loam | 1 - 1.5 | 0.30 | 433 | 120 | 299 | 153 | 100 | 144 | 217 | 60 | 100 | 77 | 50 | 72 |
Heavy Clay Loam | 1.5 - 2.0 | 0.20 | 650 | 178 | 449 | 225 | 150 | 217 | 325 | 89 | 225 | 113 | 75 | 109 |
Light Silty Clay Loam | 1 - 1.5 | 0.30 | 433 | 120 | 299 | 153 | 100 | 144 | 217 | 60 | 100 | 77 | 50 | 72 |
Heavy Silty Clay Loam | 1.5 - 2.0 | 0.20 | 650 | 178 | 449 | 225 | 150 | 217 | 325 | 89 | 225 | 113 | 75 | 109 |
Sandy Clay | >2.0 | - | NOT SUITABLE | |||||||||||
Silty Clay | >2.0 | - | NOT SUITABLE | |||||||||||
Clay | >2.0 | - | NOT SUITABLE |
Minimum and maximum trench widths are 24 and 36 inches, respectively.
** Bedroom is equivalent to 130 gallons per day.
15 Miss. Code. R. 15-77-2-5.2.7