15 Miss. Code. R. 15-77-2-5.2.7

Current through January 14, 2025
Rule 15-15-77-2-5.2.7 - Sizing

SIZING - AGGREGATE REPLACEMENT (Expanded Polystyrene System) "Horizontal" Configuration

Results of the Soil and Site Evaluation

Soil Textural Class

Ribbon Lengths (Inches)

EPA Manual Application Rate GPD/

Ft2

Absorption Area Per Bedroom**

Additional Absorption Over 2 Person Per Bedroom**

3-1 0H

1-12

2-12

3-12

1-14

3-10 H

1-12

2-12

3-12

1-14

Ft 2

Lf

Lf

Lf

Lf

Lf

Ft 2

Lf

Lf

Lf

Lf

Lf

Gravel

-

-

NOT SUITABLE

Coarse Sand

-

1.2

108

30

75

37

25

36

54

15

38

19

13

18

Medium Sand

-

1.2

108

30

75

37

25

36

54

15

38

19

13

18

Fine Sand

-

0.8

163

46

114

57

38

55

81

23

57

29

19

28

Loamy Sand

-

0.8

163

46

114

57

38

55

81

23

57

29

19

28

Sandy Loam

<.5

0.6

217

60

151

75

50

72

108

30

76

38

25

36

Light Loam

<.5

0.6

217

60

151

75

50

72

108

30

76

38

25

36

Heavy Loam

.5 - 1

0.45

289

81

201

101

67

97

144

40

101

52

33

49

Silt Loam

<1

0.45

289

81

201

101

67

97

144

40

101

52

33

49

Sandy Clay Loam

1 - 2

0.45

289

81

201

101

67

97

144

40

101

52

33

49

Light Clay Loam

1 - 1.5

0.30

433

120

299

153

100

144

217

60

100

77

50

72

Heavy Clay Loam

1.5 - 2.0

0.20

650

178

449

225

150

217

325

89

225

113

75

109

Light Silty Clay Loam

1 - 1.5

0.30

433

120

299

153

100

144

217

60

100

77

50

72

Heavy Silty Clay Loam

1.5 - 2.0

0.20

650

178

449

225

150

217

325

89

225

113

75

109

Sandy Clay

>2.0

-

NOT SUITABLE

Silty Clay

>2.0

-

NOT SUITABLE

Clay

>2.0

-

NOT SUITABLE

Minimum and maximum trench widths are 24 and 36 inches, respectively.

** Bedroom is equivalent to 130 gallons per day.

15 Miss. Code. R. 15-77-2-5.2.7

Miss Code Ann. § 41-67-3
Adopted 11/9/2014
Amended 2/11/2019