UPC section 210.0 is modified by amending the following definition:
Hydromechanical Grease Interceptor - A plumbing appurtenance or appliance that is installed in a sanitary drainage system to intercept nonpetroleum fats, oil, and grease (FOG) from a wastewater discharge and is identified by flow rate, and separation and retention efficiency. The design incorporates air entrainment, hydromechanical separation, interior baffling, or barriers in combination or separately, and one of the following:
A - External flow control, with aix intake (vent), directly connected.
B - External flow control, without air intake (vent), directly connected.
C - Without external flow control, directly connected.
These interceptors comply with the requirements of Table 1014.2.1. Hydromechanical grease interceptors are generally installed inside.
UPC section 210.0 is modified by adding the following definition:
Health Authority - Means the state health department or local public health agency that has authority established under law to enforce rules governing drinking water supply.
Minn. R. agency 222, ch. 4714, pt. 4714.0210