The agency must evaluate and apply whole effluent toxicity (WET) as WQBELs and permit conditions through the following procedures and conditions:
WQBELs determined under subpart 6 must comply with subpart 1, items A and B, except if the agency determines on an individual permit basis that chemical-specific limitations are sufficient to ensure compliance with subpart 1, items A and B.
Where the agency determines according to subpart 5 that the WET of an effluent is or may be discharged at a level that will cause, have the reasonable potential to cause, or contribute to an excursion above any standard specified in subpart 1 or 2, the following permit conditions must be established:
If the agency determines that it lacks sufficient information to establish under subpart 5 whether the WET of an effluent is or may be discharged at a level that will cause, have the reasonable potential to cause, or contribute to an excursion above any standard specified in subpart 1 or 2, the following permit conditions must be established:
The agency must apply the factors in Code of Federal Regulations, title 40, section 122.44, paragraph (d)(1)(ii), and use representative data to evaluate the WET of an effluent. The agency must apply the provisions in items A to C to evaluate the reasonable potential of the effluent to exceed a WQBEL.
T (B)(Qd) _____ Qd + Qr | > | 1.0 TUa or 0.3 TUa, as applicable |
Where:
T | = | Maximum acute toxicity of the effluent measured under item A, subitem (1), in toxic units (TUa) |
B | = | Multiplying factor from part 7052.0370, converting the measured maximum value to a 95th percentile value, except that a CV of 0.6 must be used where less than ten individual WET tests are available |
Qd | = | Effluent design flow |
Qr | = | Dilution flow allowed from the stream design flow specified in part 7052.0200, subpart 3, item A, subitem (1), including allowance for dilution from a mixing zone demonstration under part 7052.0210; or |
T(B)(X) > 1.0 TUa or 0.3 TUa, as applicable
Where:
T | = | Maximum acute toxicity of the effluent measured under item A, subitem (1), in toxic units (TUa) |
B | = | Multiplying factor from part 7052.0370 converting the measured maximum value to a 95th percentile value, except that a CV of 0.6 must be used where less than ten individual WET tests are available |
X | = | Dilution ratio established in the mixing zone demonstration under part 7052.0210, subpart 2. |
T(B)(Qd) _____ Qd + Qr | > | 1.0 TUc |
Where:
T | = | Maximum chronic toxicity of the effluent measured under item A, subitem (2), in toxic units (TUc) |
B | = | Multiplying factor from part 7052.0370, converting the measured maximum value to a 95th percentile value, except that a CV of 0.6 must be used where less than ten individual WET tests are available |
Qd | = | Effluent design flow |
Qr | = | Dilution flow allowed from the stream design flow specified in part 7052.0200, subpart 3, item A, subitem (2), including allowance for dilution from a mixing zone demonstration under part 7052.0210; or |
T (B)(X) > 1.0 TUc
Where:
T | = | Maximum chronic toxicity of the effluent measured under item A, subitem (2), in toxic units (TUc) |
B | = | Multiplying factor from part 7052.0370 converting the measured maximum value to a 95th percentile value, except that a CV of 0.6 must be used where less than ten individual WET tests are available |
X | = | 10, which represents a receiving water volume to effluent volume dilution ratio of 10 to 1, unless an alternative mixing zone demonstration is provided under part 7052.0210, subpart 2, that includes a dilution ratio other than 10 to 1 and results in a mixing zone that is no greater than the area of discharge-induced mixing, in which case X equals the dilution ratio established in the demonstration. |
The agency must establish WQBELs according to the provisions in items A to D.
Acute WET limitation | = | T (Qd + Qr) _____ Qd |
Where:
T | = | 0.3 TUa |
Qd | = | Effluent design flow |
Qr | = | Stream design flow specified in part 7052.0200, subpart 3, item A, subitem (1), including allowance for dilution from a mixing zone demonstration under part 7052.0210; or |
Acute WET limitation = T(X)
Where:
T | = | 0.3 TUa |
X | = | The dilution ratio established in the mixing zone demonstration under part 7052.0210, subpart 2. |
Chronic WET limitation | = | T (Qd + Qr) _____ Qd |
Where:
T | = | 1.0 TUc |
Qd | = | Effluent design flow |
Qr | = | Stream design flow specified in part 7052.0200, subpart 3, item A, subitem (2), including allowance for dilution from a mixing zone demonstration under part 7052.0210. |
Chronic WET limitation = T (X)
Where:
T | = | 1.0 TUc |
X | = | 10, which represents a receiving water volume to effluent volume dilution ratio of 10 to 1, unless an alternative mixing zone demonstration is provided under part 7052.0210, subpart 2, that includes a dilution ratio other than 10 to 1 and results in a mixing zone that is no greater than the area of discharge-induced mixing, in which case X equals the dilution ratio established in the demonstration. |
Minn. R. agency 167, ch. 7052, IMPLEMENTATION OF WATER QUALITY-BASED EFFLUENT LIMITS, pt. 7052.0240
Statutory Authority: MS s 115.03; 115.44