Minn. R. agency 167, ch. 7011, SECONDARY BRASS AND BRONZE INGOT PRODUCTION PLANTS, pt. 7011.1905

Current through Register Vol. 49, No. 19, November 4, 2024
Part 7011.1905 - STANDARDS OF PERFORMANCE FOR SECONDARY BRASS AND BRONZE INGOT PRODUCTION PLANTS

No owner or operator of a secondary brass or bronze ingot production plant shall cause to be discharged into the atmosphere from a reverberatory furnace any gases which:

A. contain filterable particulate matter in excess of 50 mg/dscm (0.022 gr/dscf);
B. exhibit 20 percent opacity or greater.

No owner or operator of a secondary brass or bronze ingot production plant shall cause to be discharged into the atmosphere from any electric furnace of 1,000 kg (2,205 lbs) or greater production capacity any gases which exhibit ten percent opacity or greater.

No owner or operator of a secondary brass or bronze ingot production plant shall cause to be discharged into the atmosphere from any blast (cupola) furnace of 250 kg/hr (550 lb/hr) or greater production capacity any gases which exhibit ten percent opacity or greater.

No owner or operator of a secondary brass or bronze ingot production plant shall cause to be discharged into the atmosphere from any electric furnace of less than 1,000 kg (2,205 lbs) production capacity or any blast (cupola) furnace of less than 250 kg/hr (550 lb/hr) production capacity any gases which exceed the limits of parts 7011.0700 to 7011.0735 for particulate emissions, and exhibit 20 percent opacity or greater.

Minn. R. agency 167, ch. 7011, SECONDARY BRASS AND BRONZE INGOT PRODUCTION PLANTS, pt. 7011.1905

18 SR 614
41 SR 763

Statutory Authority: MS s 116.07