Source Gas Volume, DSCFMa | Concentration GR/DSCFb |
7,000 or less | 0.100 |
8,000 | 0.096 |
9,000 | 0.092 |
10,000 | 0.089 |
20,000 | 0.071 |
30,000 | 0.062 |
40,000 | 0.057 |
50,000 | 0.053 |
60,000 | 0.050 |
80,000 | 0.045 |
100,000 | 0.042 |
120,000 | 0.040 |
140,000 | 0.038 |
160,000 | 0.036 |
180,000 | 0.035 |
200,000 | 0.034 |
300,000 | 0.030 |
400,000 | 0.027 |
500,000 | 0.025 |
600,000 | 0.024 |
800,000 | 0.021 |
1,000,000 or more | 0.020 |
Interpolation of the data in this part for airflow rates between 7,000 dscfm and 1,000,000 dscfm must use the equation:
c = 1.7627 x FRcorrected-0.3241
where:
c = concentration limit in gr/dscf
FRcorrected = gas volume in dscfm
aDry standard cubic feet per minute
bGrains per dry standard cubic foot.
Minn. R. agency 167, ch. 7011, INDUSTRIAL PROCESS EQUIPMENT, pt. 7011.0735
Statutory Authority: MS s 116.07