This part applies to the owner or operator of a stationary source claiming mechanical finishing operations that emit only particulate matter as a conditionally insignificant activity. To qualify as a conditionally insignificant activity under this part, all mechanical finishing operations at the stationary source must be included in the limits under subpart 2. If lead is a component of any mechanical finishing operation at the stationary source, this part does not apply. All particulate matter is considered filterable particulate matter under this part.
The owner or operator of a stationary source claiming mechanical finishing operations as a conditionally insignificant activity must:
The owner or operator of a stationary source claiming mechanical finishing operations as a conditionally insignificant activity
The owner or operator claiming mechanical finishing operations as a conditionally insignificant activity must calculate emissions of particulate matter from each mechanical finishing operation according to the following equations:
Where:
E = actual emissions from the mechanical finishing operation, in pounds per calendar year.
Ec = actual emissions from the control equipment, in pounds per calendar year
Eu = actual emissions that are uncaptured by the control equipment, in pounds per calendar year.
OP = hours of operations of the control equipment per calendar year
EF = design concentration for particulate matter from the control equipment, in grains per standard cubic foot, but if the manufacturers design value is unknown, then the default value is 0.07 grains per standard cubic foot for cyclones or 0.03 grains per standard cubic foot for fabric filters.
QAir = design airflow rate from the control equipment, in standard cubic feet per minute.
R = the ratio of emissions that are uncaptured by the control equipment to the emissions that are captured and controlled by the control equipment. When emissions are captured through a total enclosure and vented to any type of control equipment, the value of R is 0. When emissions are captured through a certified hood, the value of R is 3.57 when vented to a fabric filter or 1.14 when vented to a cyclone or other type of control equipment. When emissions are captured through an uncertified hood, the value of R is 14.29 when vented to a fabric filter or 4.54 when vented to a cyclone or other type of control equipment.
Minn. R. agency 167, ch. 7008, pt. 7008.4110
Statutory Authority: MS s 116.07