Part 5225.1140 - ATTENDANCE OF HOBBY BOILERS
Subpart 1. [Repealed, 21 SR 1897]
Subp. 2. [Repealed, 21 SR 1897]
Subp. 3.Hobby boiler.

A hobby boiler may not be left unattended when in operation and members of the public are present. For purposes of this part, a traction engine may be considered as not being in operation when all of the following conditions exist:

A. the water level is at least one-third of the water gage glass;
B. the header or dome valve is in a closed position;
C. the draft doors are closed;
D. the fire is banked or extinguished; and
E. the boiler pressure is at least 20 pounds per square inch below the safety valve relieving pressure.

Minn. R. Part 5225.1140

19 SR 591; 21 SR 1897; L 2007 c 140 art 9 s 27; art 13 s 4