Minn. R. agency 151, ch. 1346, ch. 8, pt. 1346.6014

Current through Register Vol. 49, No. 12, September 16, 2024
Part 1346.6014 - IFGC APPENDIX E, TABLE E-1

IFGC Appendix E, Table E-1

Residential Combustion Air Required Volume

(Required Interior Volume Based on Input Rating of Appliances)

Known Air Infiltration Rate (KAIR) Method (ft3)
Fan AssistedNon-Fan-Assisted
Input Rating (Btu/hr)Standard Method (ft3)19941 to PresentPre 1994219941 to PresentPre 19942
5,000250375188525263
10,0005007503751,050525
15,0007501,1255631,575788
20,0001,0001,5007502,1001,050
25,0001,2501,8759382,6251,313
30,0001,5002,2501,1253,1501,575
35,0001,7502,6251,3133,6751,838
40,0002,0003,0001,5004,2002,100
45,0002,2503,3751,6884,7252,363
50,0002,5003,7501,8755,2502,625
55,0002,7504,1252,0635,7752,888
60,0003,0004,5002,2506,3003,150
65,0003,2504,8752,4386,8253,413
70,0003,5005,2502,6257,3503,675
75,0003,7505,6252,8137,8753,938
80,0004,0006,0003,0008,4004,200
85,0004,2506,3753,1888,9254,463
90,0004,5006,7503,3759,4504,725
95,0004,7507,1253,5639,9754,988
100,0005,0007,5003,75010,5005,250
105,0005,2507,8753,93811,0255,513
110,0005,5008,2504,12511,5505,775
115,0005,7508,6254,31312,0756,038
120,0006,0009,0004,50012,6006,300
125,0006,2509,3754,68813,1256,563
130,0006,5009,7504,87513,6506,825
135,0006,75010,1255,06314,1757,088
140,0007,00010,5005,25014,7007,350
145,0007,25010,8755,43815,2257,613
150,0007,50011,2505,62515,7507,875
155,0007,75011,6255,81316,2758,138
160,0008,00012,0006,00016,8008,400
165,0008,25012,3756,18817,3258,663
170,0008,50012,7506,37517,8508,925
175,0008,75013,1256,56318,3759,188
180,0009,00013,5006,75018,9009,450
185,0009,25013,8756,93819,4259,713
190,0009,50014,2507,12519,9509,975
195,0009,75014,6257,31320,47510,238
200,00010,00015,0007,50021,00010,500
205,00010,25015,3757,68821,52510,763
210,00010,50015,7507,87522,05011,025
215,00010,75016,1258,06322,57511,288
220,00011,00016,5008,25023,10011,550
225,00011,25016,8758,43823,62511,813
230,00011,50017,2508,62524,15012,075

1The 1994 date refers to dwellings constructed under the 1994 Minnesota Energy Code. The default KAIR used in this section of the table is 0.20 ACH.

2This section of the table is to be used for dwellings constructed prior to 1994. The default KAIR used in this section of the table is 0.40 ACH.

Minn. R. agency 151, ch. 1346, ch. 8, pt. 1346.6014

34 SR 537

Statutory Authority: MS s 326B.101; 326B.106; 326B.13