Minn. R. Part 1305.2510

Current through Register Vol. 48, No. 51, June 17, 2024
Part 1305.2510 - SECTION 2510, LATHING AND FURRING FOR CEMENT PLASTER (STUCCO)

IBC section 2510.6 is amended to read as follows:

2510.6Water-resistive barriers. Water-resistive barriers shall be installed as required in Section 1403.2 and, where applied over wood-based sheathing, shall include a water-resistive, vapor-permeable barrier with a performance at least equivalent to two layers of Grade D paper.

Exception: Where the water-resistive barrier that is applied over wood-based sheathing has a water resistance equal or greater than that of 60-minute Grade D paper and is separated from the stucco by an intervening, substantially non-water-absorbing layer or drainage space.

Minn. R. Part 1305.2510

39 SR 1605
44 SR 609 eff. 3/31/2020