Minn. R. Part 1305.1705

Current through Register Vol. 48, No. 51, June 17, 2024
Part 1305.1705 - SECTION 1705, REQUIRED VERIFICATION AND INSPECTION
Subpart 1.IBC Table 1705.3.

IBC Table 1705.3 is amended as follows:

A. Add "Xc" to the "Periodic" column, row "7. Inspection of concrete and shotcrete placement for proper application techniques."
B. Add footnote "c." to read as follows:
c. Exception: Periodic verification and inspection is permitted, upon approval of the structural engineer of record and the building official.
Subp. 2.IBC section 1705.4.

IBC section 1705.4 is amended by adding the following sentence to the end of the section: "Periodic verification and inspection of grout placement is permitted, upon approval of the structural engineer of record and the building official."

Minn. R. Part 1305.1705