Minn. R. agency 144, ch. 4731, IRRADIATORS, pt. 4731.6180

Current through Register Vol. 49, No. 29, 2025
Part 4731.6180 - PERSONNEL MONITORING
Subpart 1.Irradiator operators.

Irradiator operators must wear a personnel dosimeter while operating a panoramic irradiator or while in the area around the pool of an underwater irradiator. The personnel dosimeter must be capable of detecting high energy photons in the normal and accident dose ranges. Each personnel dosimeter must be assigned to and worn by only one individual. Film badges must be replaced at least monthly and other personnel dosimeters that require replacement must be replaced at least quarterly. All personnel dosimeters must be evaluated at least quarterly or promptly after replacement, whichever is more frequent.

Subp. 2.Other personnel.

Other individuals who enter the radiation room of a panoramic irradiator must wear a dosimeter, which may be a pocket dosimeter. For groups of visitors, only two people who enter the radiation room are required to wear dosimeters. If pocket dosimeters are used to meet the requirements of this subpart, a check of their response to radiation must be done at least annually. Acceptable dosimeters must read within plus or minus 30 percent of the true radiation dose.

Minn. R. agency 144, ch. 4731, IRRADIATORS, pt. 4731.6180

29 SR 755
46 SR 790

Statutory Authority: MS s 144.1202; 144.1203