Section R. 460.20310 - Galvanized or aluminum pipe prohibited for direct burial or submerged useRule 310.
(1) In addition to the requirements contained in 49 C.F.R.§ 192.461, which is adopted by reference in R 460.20606, an operator shall not utilize galvanized pipe for direct burial or submerged use.(2) The requirements contained in 49 C.F.R. § 192.455(e), which is adopted by reference in R 460.20606, are superseded by the requirement that an operator shall not utilize aluminum pipe for direct burial or submerged use.Mich. Admin. Code R. 460.20310
1998-2000 AACS; 2019 MR 1, Eff. 1/3/2019