Mich. Admin. Code R. 408.7069

Current through Vol. 24-24, January 15, 2025
Section R. 408.7069 - Applicability of national standard and rules of board

Rule 69.

(1) This rule applies to manlifts, as described in the ASME A90.1-2009, which is adopted by reference in R 408.7003, that are used only to carry plant personnel in granaries, flour mills, parking garages, and similar buildings or occupancies. Belt manlifts shall not be used by the public and, if located in buildings to which the public has access, shall be located in an enclosure that is protected by self-closing, spring-locked doors. Keys to the doors shall be available to employees. The use of belt manlifts during construction is prohibited.
(2) The hoistway enclosure shall comply with the Michigan building code, R 408.30401 to R 408.30547, and shall maintain the fire rating of the structure.
(3) The travel of any single belt manlift installed after February 14, 1968 shall not exceed 100 feet.

Mich. Admin. Code R. 408.7069

2003 AACS; 2005 AACS; 2010 AACS; 2014 AACS