Current through Vol. 24-24, January 15, 2025
Section R. 408.7046 - Pressure gauge fittingsRule 46. Section 3.19.4.5 of the ASME A17.1 code is amended to read as follows:
3.19.4.5 A new hydraulic machine must be provided with the necessary permanent pressure gauge snap-on fittings or permanent gauges, with a shut off valve to allow pressure readings at each pump for checking operating pressures. The gauge or fitting must be located on the jack side of the check valve or immediately adjacent to the hydraulic control valve.Mich. Admin. Code R. 408.7046