Section R. 408.30758a - High and low drinking fountains minimum numberRule 758a. Section 410.3.1 is added to the code to read as follows:
410.3.1. High and low drinking fountains minimum number. Where drinking fountains are required, no fewer than 2 drinking fountains shall be provided. One drinking fountain shall comply with the requirements for people who use a wheelchair, and 1 drinking fountain shall comply with the requirements for standing individuals. Exceptions:
1. A single drinking fountain with 2 separate spouts that complies with the requirements for individuals who use a wheelchair and standing individuals shall be allowed to be substituted for 2 separate drinking fountains.2. Where drinking fountains are primarily for children's use, the drinking fountains for people using wheelchairs shall be allowed to comply with the children's provisions in ICC A117.1 and drinking fountains for standing children shall be allowed to have the spout at 30 inches, 762 mm, minimum above the floor.3. Referencing building code for all height requirements of drinking fountains and water coolers.Mich. Admin. Code R. 408.30758a
1979 AC; 1980 AACS; 1985 AACS; 1997 AACS; 2023 MR 22, Eff. 3/12/2024