Rule 755. Table 1102.4 of the code is amended to read as follows:
TABLE 1102.4
BUILDING STORM SEWER PIPE
MATERIAL | STANDARD |
Acrylonitrile butadiene styrene (ABS) plastic pipe in IPS diameters, including Schedule 40, DR 22 (PS 200) and DR 24 (PS 140); with a solid, cellular core or composite wall. | ASTM D2661; ASTM F628; ASTM F1488; CSA B181.1; CSA B182.1 |
Cast-iron pipe | ASTM A74; ASTM A888; CISPI 301 |
Concrete pipe | ASTM C14; ASTM C76; CSA A257.1M; CSA A257.2M |
Copper or copper-alloy tubing (Type K, L, M or DWV) | ASTM B75; ASTM B88; ASTM B251; ASTM B306 |
Polyethylene (PE) plastic pipe | ASTM F667; ASTM F2306/F2306; ASTM F2648/F2648M |
Polypropylene (PP) plastic pipe | ASTM F2736; ASTM F2764; CSA B182.13 |
Polyvinyl chloride (PVC) plastic pipe (Type DWV, SDR26, SDR35, SDR41, PS50 or PS100) in IPS diameters, including Schedule 40, DR 22 (PS 200) and DR 24 (PS 140); with a solid, cellular core or composite wall | ASTM D2665; ASTM D3034; ASTM F891; ASTM F1488; CSA B181.2; CSA B182.2; CSA B182.4 |
Vitrified clay pipe | ASTM C4; ASTM C700 |
Stainless steel drainage systems, Type | ASME A112.3.1 |
316L |
Mich. Admin. Code R. 408.30755