Mich. Admin. Code R. 408.30458

Current through Vol. 24-19, November 1, 2024
Section R. 408.30458 - Elevators and conveying systems

Rule 458.

Sections 3001.1, 3001.2, 3001.4, 3002.5, 3002.6, 3003.1, and 3003.2, of the code are amended and sections 3001.2.1, 3001.2.2, 3003.1.5 and 3004.5 are added to the code to read as follows:

3001.1. Scope. The design, construction, installation, alteration, and repair of elevators and conveying systems and their equipment shall conform with the requirements of the Michigan elevator laws and rules, MCL 408.801 to 408.824, MCL 338.2151 to 338.2160, and R 408.7001 to R 408.8695 and this chapter. Installation or construction in flood hazard areas established in section 1612.3 shall comply with ASCE 24 listed in chapter 35.
3001.2. Other devices. Other devices shall conform to the requirements of sections 3001.2.1 and 3001.2.2 of the code.
3001.2.1. Conveyors. Conveyors and related equipment shall conform to the requirements of ASME B20.1 listed in chapter 35.
3001.2.2. Automotive lifts. Automotive lifts shall conform to the requirements of ALI ALCTV listed in chapter 35.
3001.4. Change in use. A change in use of an elevator from freight to passenger, passenger to freight, or from 1 freight class to another freight class shall comply with the requirements of the Michigan elevator code, R 408.7001 to R 408.8695.
3002.5. Emergency doors. Where an elevator is installed in a single blind hoistway or on the outside of a building, there shall be installed in the blind portion of the hoistway or blank face of the building, an emergency door in accordance with the requirements of the Michigan elevator code, R 408.7001 to R 408.8695.
3002.6. Prohibited doors. Doors, other than hoistway doors and the elevator car door, shall be prohibited at the point of access to an elevator car.
3003.1. Standby power. In buildings and structures where standby power is required or furnished to operate an elevator, the operation shall be in accordance with sections 3003.1.1 to 3003.1.5 of the code. 3003.1.5. Lighting. Where standby power is connected to elevators, the machine room, car top, pit, and landing lighting shall be connected to the standby power source. 3003.2 Fire-fighters' emergency operation. Elevators shall be provided with phase I emergency recall operation and phase II emergency in-car operation in accordance with the requirements of the Michigan elevator code, R 408.7001 to R 408.8695.
3004.5. Construction at bottom of hoistway. Pits extending to the ground shall have noncombustible floors and be designed as to prevent entry of ground water into the pit. The pit floor of any hoistway not extending to the ground shall be of fire-resistive construction having a fire-resistance rating at least equal to that required for the hoistway enclosure.

Mich. Admin. Code R. 408.30458

1988 AACS; 1992 AACS; 1995 AACS; 2001 AACS; 2004 AACS; 2008 AACS; 2016 MR 24, Eff. 4/20/2017