Section R. 400.2376 - Smoke detection equipmentRule 376.
(1) At least 1 single station smoke detector shall be installed at the following locations:(a) Between the sleeping areas and the rest of the home. In homes with more than 1 sleeping area, a smoke detector shall be installed to protect each separate sleeping area.(b) On each occupied floor, in the basement, and in areas of the home which contain flame- or heat-producing equipment.(2) Approved heat detectors may be installed in the kitchen and in other areas of the home containing flame- or heat-producing equipment in lieu of smoke detectors.(3) If batteries are used as a source of energy, they shall be replaced in accordance with the recommendations of the alarm equipment manufacturer.(4) Detectors shall be tested and examined as recommended by the manufacturer.(5) This rule does not apply to the following:(a) Adult foster care small group homes which are licensed effective March 27, 1980, and which meet the requirements of section 21 of Act No. 218 of the Public Acts of 1979, as amended, being S400.721 of the Michigan Compiled Laws.(b) Adult foster care small group homes licensed or proposed to be licensed for more than 6 adults.Mich. Admin. Code R. 400.2376