Mich. Admin. Code R. 408.13875

Current through Vol. 24-21, December 1, 2024
Section R. 408.13875 - Powder-actuated tool defects and misfires

Rule 3875.

(1) In case of a misfire, the operator shall hold the powder-actuated tool in the operating position for not less than 30 seconds. The operator shall then try to operate the tool a second time.

The operator shall wait another 30 seconds, holding the tool in the operating position, and the the operator shall proceed to remove the explosive load in strict accordance with the manufacturer's instructions.

(2) Misfired cartridges shall be placed carefully in a container filled with water and shall be disposed of in a safe manner.

Mich. Admin. Code R. 408.13875

1979 AC; 1983 AACS