Section R. 408.13395f - Lineman's body belt and pole strap systems

Rule 3395f. An employer shall ensure that all linemans body belt and pole strap systems meet the following tests:

(a) A dielectric test of 819.7 volts, AC, per centimeter, 25,000 volts per foot, for 3 minutes without visible deterioration.
(b) A leakage test of 98.4 volts, AC, per centimeter, 3,000 volts per foot, with a leakage current of no more than 1 mA.
(c) A flammability test in accordance with Table F "Flammability Test."

TABLE F

FLAMMABILITY TEST

Test Method

Criteria for Passing Test

1. Vertically suspend a 19.7-inch (500-mm) length of strapping supporting a 220.5-lb (100-kg) weight.

Any flames on the position strap must self-extinguish.

2. Use a butane or propane burner with a 3-inch (76-mm) flame.

3. Direct the flame to an edge of the strapping at a distance of 1 inch (25 mm).

The positioning strap must continue to support the 220.5-lb (100-kg) mass.

4. Remove the flame after 5 seconds.

5. Wait for any flames on the positioning strap to stop burning.