Mich. Admin. Code R. 408.12716

Current through Vol. 24-21, December 1, 2024
Section R. 408.12716 - Machines and equipment; controls

Rule 2716.

(1) A machine shall have a mechanical or electrical power control to permit the operator to cut off the power from the machine without leaving his or her position at the work station.
(2) A woodworking machine shall not automatically restart upon restoration of power after a power failure. A machine wired to a 110 volt line before November 15, 1971, is excepted from this rule.
(3) Operating controls shall be located within reach of the operator while the operator is at his or her regular work station, making it unnecessary to reach over the cutters. The controls shall be installed to eliminate the danger of accidental activation. This subrule does not apply to a constant pressure control used only for setup purposes.

Mich. Admin. Code R. 408.12716

1979 AC; 1997 AACS; 2013 AACS