Rule 210.
TABLE 1
INITIAL PERIOD (LESS THAN 24 HOURS)
Maximum Unbraced Height of Unreinforced Masonry
Above its Base or Highest Line of Bracing for Resisting 20 mph Wind
Nominal Thickness | Unit Weight of Masonry | ||
Light Weight(1) (<105 pcf) | Medium Weight(2) (105 to <125pcf) | Normal Weight(3) ([GREATER THAN EQUAL TO]125 pcf) | |
Maximum Height | Maximum Height | Maximum Height | |
4" | 8'-0" | 8'-0" | 8'-0" |
6" | 8'-0" | 8'-0" | 8'-0" |
8" | 9'-4" | 10'-0" | 12'-0" |
10" | 13'-4" | 14'-8" | 17-4" |
12" | 18'-0" | 20'-0" | 24'-0" |
TABLE 2(5)
INTERMEDIATE PERIOD (GREATER THAN 24 HOURS)
Maximum Unbraced Height of Unreinforced Masonry
Above its Base or Highest Line of Bracing for Resisting 35 mph Wind
Nominal Thickness | Unit Weight of Masonry | Unbonded Masonry(4) | ||
Light Weight(1) (<105 pcf) | Medium Weight(2) (105 to <125pcf) | Normal Weight(3) ([GREATER THAN EQUAL TO]125 pcf) | ||
Maximum Height | Maximum Height | Maximum Height | Maximum Height | |
4" | 8'-0" | 8'-0" | 8'-0" | 8'-0" |
6" | 8'-0" | 8'-0" | 8'-0" | 8'-0" |
8" | 8'-0" | 8'-0" | 8'-0" | 8'-0" |
10" | 8'-0" | 8'-0" | 8'-8" | 8'-0" |
12" | 9'-4" | 10'-0" | 10'-8" | 8'-0" |
TABLE 3(5)
INTERMEDIATE PERIOD (GREATER THAN 24 HOURS)
Maximum Unbraced Height of Unreinforced Masonry
Above its Base or Highest Line of Bracing for Resisting 20 mnh Wind
Nominal Thickness | Unit Weight of Masonry | Unbonded Masonry(4) | ||
Light Weight(1) (<105 pcf) | Medium Weight(2) (105 to <125pcf) | Normal Weight(3) ([GREATER THAN EQUAL TO]125 pcf) | ||
Maximum Height | Maximum Height | Maximum Height | Maximum Height | |
4" | 8'-0" | 8'-0" | 8'-0" | 8'-0" |
6" | 9'-4" | 10'-0" | 10'-8" | 8'-0" |
8" | 14'-8" | 15'-4" | 16'-8" | 9'-4" |
10" | 18'-8" | 20'-0" | 22'-0" | 13'-4" |
12" | 23'-4" | 25'-4" | 28'-0" | 18'-0" |
Mich. Admin. Code R. 408.40210