Browse as ListSearch Within- Section R. 325.10701 - Purpose
- Section R. 325.10702 - Evaluation of adequacy and condition of public water supplies; sanitary surveys
- Section R. 325.10703 - On-site inspections and surveillance observations
- Section R. 325.10704 - Coliform sampling
- Section R. 325.10704a - Total coliform; general
- Section R. 325.10704b - Total coliform; analytical methods
- Section R. 325.10704c - Total coliform; general monitoring
- Section R. 325.10704d - Total coliform; routine monitoring; noncommunity; serving 1,000 or fewer people; groundwater
- Section R. 325.10704e - Total coliform; routine monitoring; community; serving 1,000 or fewer people; groundwater
- Section R. 325.10704f - Total coliform; routine monitoring; subpart H; serving 1,000 or fewer people
- Section R. 325.10704g - Total coliform; routine monitoring; community and noncommunity; serving more than 1,000 people
- Section R. 325.10704h - Total coliform; repeat monitoring; E. coli
- Section R. 325.10704i - Total coliform; treatment technique triggers; assessments
- Section R. 325.10704j - Total coliform; violations
- Section R. 325.10704k - Total coliform; reporting and recordkeeping
- Section R. 325.10705 - Collection and analysis of samples for coliform bacteria; community water systems
- Section R. 325.10706 - Collection and analysis of samples for coliform bacteria; noncommunity water system
- Section R. 325.10707 - Repeat monitoring for coliform bacteria
- Section R. 325.10707a - Invalidation of total coliform samples
- Section R. 325.10707b - General notification requirements for total coliform and fecal coliform/Escherichia coli (E. coli)
- Section R. 325.10708 - Collection of additional samples
- Section R. 325.10709 - Special purpose and invalidated samples
- Section R. 325.10710 - Collection and analysis of samples for inorganic chemicals
- Section R. 325.10710a - Lead and copper in tap water; monitoring requirements
- Section R. 325.10710b - Monitoring requirements for water quality parameters
- Section R. 325.10710c - Monitoring requirements for lead and copper in source water
- Section R. 325.10710d - Reporting requirements for lead, copper, and corrosion control
- Section R. 325.10711 - Rescinded
- Section R. 325.10712 - Rescinded
- Section R. 325.10713 - Rescinded
- Section R. 325.10714 - Rescinded
- Section R. 325.10715 - Rescinded
- Section R. 325.10716 - Collection and analysis of samples for VOCs
- Section R. 325.10717 - Collection and analysis of samples for synthetic organic chemicals
- Section R. 325.10717a - Rescinded
- Section R. 325.10717b - Special monitoring
- Section R. 325.10717c - Rescinded
- Section R. 325.10717d - Collection and analysis of samples for per- and polyfluoroalkyl substances
- Section R. 325.10718 - Rescinded
- Section R. 325.10719 - Rescinded
- Section R. 325.10719a - Rescinded
- Section R. 325.10719b - Rescinded
- Section R. 325.10719c - Rescinded
- Section R. 325.10719d - Rescinded
- Section R. 325.10719e - Disinfectant residuals, disinfection byproducts, and disinfection byproduct precursors; monitoring requirements
- Section R. 325.10719f - Disinfectant residuals, disinfection byproducts, and disinfection byproduct precursors; reporting and recordkeeping
- Section R. 325.10719g - Rescinded
- Section R. 325.10719h - Disinfection byproducts; routine monitoring
- Section R. 325.10719i - Disinfection byproducts; monitoring plan
- Section R. 325.10719j - Disinfection byproducts; reduced monitoring
- Section R. 325.10719k - Disinfection byproducts; conditions requiring increased monitoring
- Section R. 325.10719l - Disinfection byproducts: operational evaluation levels
- Section R. 325.10719m - Rescinded
- Section R. 325.10719n - Disinfection byproducts; reporting and recordkeeping requirements
- Section R. 325.10720 - Filtration and disinfection; filtration sampling requirements
- Section R. 325.10720a - Filtration and disinfection; reporting and recordkeeping
- Section R. 325.10720b - Enhanced treatment for Cryptosporidium; source water monitoring
- Section R. 325.10720c - Enhanced treatment for Cryptosporidium; disinfection profiling and benchmarking; making significant change in disinfection practice
- Section R. 325.10720d - Enhanced treatment for Cryptosporidium; developing disinfection profile and benchmark
- Section R. 325.10720e - Enhanced treatment for Cryptosporidium; reporting and recordkeeping requirements
- Section R. 325.10721 - Rescinded
- Section R. 325.10722 - Filtration and disinfection; disinfection profiling and benchmarking
- Section R. 325.10724 - Rescinded
- Section R. 325.10725 - Radionuclides; applicability; monitoring generally; reporting
- Section R. 325.10726 - Radionuclides; initial monitoring for gross alpha particle activity, radium-226, radium-228, and uranium
- Section R. 325.10728 - Radionuclides; reduced monitoring for gross alpha particle activity, radium-226, radium-228, and uranium
- Section R. 325.10729 - Radionuclides; compositing; substituting gross alpha for radium-226 or uranium
- Section R. 325.10730 - Radionuclides; monitoring requirements for beta particle and photon radioactivity; applicability
- Section R. 325.10731 - Sample analyses; approved laboratories and personnel
- Section R. 325.10732 - Specific testing frequencies; sample locations and parameters
- Section R. 325.10733 - Modification of monitoring requirements for type I public water supplies which supply water to additional public water supplies
- Section R. 325.10734 - Required reporting to the department
- Section R. 325.10735 - Vigilance of threats or hazards; notification to department
- Section R. 325.10736 - Rescinded
- Section R. 325.10737 - Rescinded
- Section R. 325.10738 - Rescinded
- Section R. 325.10739 - Groundwater supply rules; groundwater source microbial monitoring and analytical methods
- Section R. 325.10739a - Groundwater supply rules; compliance monitoring
- Section R. 325.10739b - Groundwater supply rules; reporting and recordkeeping