Md. Code Regs. 13B.07.05.02

Current through Register Vol. 51, No. 12, June 14, 2024
Section 13B.07.05.02 - Capital Guidelines

Space allocation guidelines for college campuses are as follows:

Room Use CategorySpace Factor by Size of FTDE
HEGIS CodeSpaceBase3000 & Under3001 & Up
100Classroom FacilitiesWSCH11.501.11
110Classroom
200Laboratory FacilitiesWSCH27.005.83
210Class Laboratory
220Open LaboratoryFTDE4.204.20
300OfficeFTEF3166.00166.00
FT Staff
Student Offices4
320Testing & Tutoring CentersFTDE5Core of 1,500 NASF and 0.5 NASF/FTDE in excess of 1,500 FTDE.
400Library
410Study/SeatingFTDE6.256.25
420StackBVE6.10-.10+
400-455ProcessingPercent of 420 with minimum of 1,200 NASF7.40.40
500Special Use
520Physical Education-Pool, Gym, and Fitness/Wellness CenterFTDE8Core of 28,000 NASF (consisting of 14,000 for a gym, 8,000 for a pool, and 6,000 for a fitness center) and 10 NASF/FTDE in excess of 1,500 FTDE and 6,000 NASF of service space (consisting of 3,500 for lockers and 2,500 for storage).
530Audiovisual, Radio, TVFTDECore of 1,600 NASF and 0.8 NASF/FTDE in excess of 1,500 FTDE up to 3,000 FTDE and 2 NASF/FTDE in excess of 3,000 FTDE.
580GreenhouseCampusCore of 1,000 NASF
600General Use
610AssemblyFTDECore of 12,000 NASF and 2 NASF/FTDE in excess of 1,500 FTDE.
620ExhibitionFTDECore of 1,500 NASF and 0.5 NASF/FTDE in excess of 1,500 FTDE.
630Food FacilitiesPHC910.28.4
650Lounge FacilitiesPHC103.03.0
660MerchandisingFTDECore of 1,600 NASF and 0.5 NASF/FTDE in excess of 1,500 FTDE.
680Meeting SpaceFTDECore of 6,000 NASFCore of 8,000 NASF
700Support
710Data Processing, TelecommFTDE11Core of 2,500 NASF for the first 4,000 FTDE and 0.75 NASF/FTDE beyond 4,000 FTDE.
720-745Shops, Storage, Vehicle Storage, and RepairTotal Campus Allowance minus this category120.040.04
750Central ServiceFTDECore of 4,000 NASF for the first 4,000 FTDE and 1 NASF/FTDE beyond 4,000 FTDE.
760Hazardous MaterialsTotal Storage2% of existing inventory in Room Use Categories 720-745.
800Health CareFTDECore of 500 NASF and 0.2 NASF/FTDE in excess of 1,500 FTDE.

1WSCH-Lecture. Weekly student contact hours for on-campus day students in credit courses and eligible noncredit courses where instruction is lecture.

2WSHC-Lab. Weekly student contact hours for on-campus day students in credit courses and eligible noncredit courses where instruction is lab.

3FTEF-Full-time equivalent faculty, including librarians, plus 25% of all part-time faculty.

41,120 square feet maximum for student offices.

5FTDE-Full-time day equivalent is total credit hours taught on campus between 8 a.m. and 5 p.m. divided by 15 credit hours.

6BVE-Bound volume equivalent which is 20,000 BVE for the first 1,000 FTE and 1,000 BVE for every 100 FTE above 1,000.

7A minimum allowance is needed for cataloging, binding, and maintenance regardless of collection size.

8Minimum size of gym is 14,000 NASF for activity space, 8,000 NASF for pool, 6,000 NASF for fitness space, 3,500 NASF for lockers, and 2,500 NASF for storage.

9PHC-Planning headcount is 50% of FTDE for on-campus credit and eligible noncredit courses plus FTEF and FT Staff and includes space for seating, preparation, and storage.

10Allowance includes quiet, study, and building lounges.

11FTDE for on-campus credit courses and eligible noncredit courses.

12Allowance related to required service space on campus total square footage.

13 Computed need in any larger institutional size category may not be less than the maximum amount for any smaller institutional size category.

Md. Code Regs. 13B.07.05.02

Regulations .02 and new Regulation .02 adopted effective April 15, 2002 (29:7 Md. R. 621); amended effective 43:25 Md. R. 1385, eff. 12/19/2016